Identify the framing layout on wall plates.
Identification should include
- locating rough openings, corners, and wall Ts
- ensuring that stud layout is 16 inches or 24 inches OC, as required by plans
- ensuring that door and window openings are of the proper width, within +/- 1/16 inch
- identifying wall plate layout marks
- stocking proper components.
Process/Skill Questions:
- What are special wall framing details?
NCCER Carpentry Standards
Level One, Module Six (27111-13): Wall Systems
Module Six (27111-13) describes the procedures for laying out and framing walls, including roughing-in door and window openings, constructing corners and partition Ts, bracing walls, and applying sheathing. The module also includes estimating materials required to frame walls.