Install various ground fault circuit interrupter (GFCI) and arc fault circuit interrupter (AFCI) devices.

Installation should include

  • identifying a breaker-type and a receptacle-type GFCI
  • identifying a feed-through GFCI receptacle
  • identifying an AFCI breaker type
  • connecting a GFCI and an AFCI breaker in single-phase service panel
  • connecting a combination GFCI/AFCI device
  • connecting a GFCI receptacle as feed-through and in-line on specified circuits.

All connections must be complete and in accordance with manufacturer guidelines and the NEC.

Process/Skill Questions:

  • Where are GFCIs required?
  • Where are AFCIs required?
  • What is the function of a GFCI?
  • How is a GFCI tested?
  • What is the function of an AFCI?